Root Cause
One of the two nodes in the Production US cluster (aks-system-96920573-vmss000000) became unresponsive at approximately 04:52 UTC, most likely due to memory exhaustion. As a result, critical workloads, including ria-api and ria-services, were unable to continue running on the affected node. Although a second node remained available, it had already reached its maximum pod capacity and could not accommodate the impacted workloads. Service availability was therefore affected until the failed node was automatically rebooted by AKS and returned to a healthy state.
Resolution
AKS automatically rebooted the affected node, restoring cluster capacity and allowing the impacted workloads to recover. Service was fully restored at approximately 05:33 UTC once the node returned to a healthy state and application services resumed normal operation.